( 1) DYT電液推杆
電液推杆具有體積小、動作靈活、工作平穩的特點,可帶負荷啟動,推拉力大,有過載保護裝置。能適應遠距離、危險及高空的地方控製作業。其推拉型式有單推、單拉和推拉;調速型式有推調速、拉調速、推拉調速或均不調速;鎖定型式有推鎖定、拉鎖定、推拉鎖定或推拉均不鎖定。推杆行程: 50~ 3000mm。
/mm
型號 | H | L | L1 | L2 | LA | LE | φ 2 | φ 3 | KK | ||||||||
C | J | C | J | C | J | C | J | C | J | C | J | C | J | C | J | C | |
DYT2500~7000 | 200 | 1090 | 645 | 790 | 210 | 400 | 260 | 170 | 170 | 240 | 240 | 160 | 160 | 30 | 30 | M24× 1.5 | M24× 1.5 |
DYT7000~14000 | 230 | 1090 | 685 | 790 | 260 | 400 | 330 | 230 | 230 | 300 | 300 | 220 | 220 | 30 | 30 | M27× 2 | M27× 2 |
DYT14000~21000 | 230 | 1300 | 685 | 900 | 260 | 450 | 330 | 230 | 230 | 300 | 300 | 220 | 220 | 35 | 35 | M27× 2 | M27× 2 |
DYT21000~40000 | 250 | 1400 | 750 | 1000 | 260 | 500 | 300 | 315 | 315 | 390 | 390 | 300 | 300 | 35 | 35 | M33× 2 | M33× 2 |
DYT40000~70000 | 270 | 1500 | 750 | 1050 | 270 | 550 | 340 | 315 | 315 | 390 | 390 | 300 | 300 | 40 | 40 | M42× 2 | M42× 2 |
DYT70000~150000 | 380 | 1700 | 820 | 1200 | 300 | 650 | 360 | 345 | 345 | 450 | 450 | 330 | 330 | 55 | 55 | M60× 2.5 | M60× 2.5 |
注: 1.表中型號後的數字表示推力範圍(單位為 N)。
2.用戶按型號表示方法,標明使用要求或在型號外另加說明。電動機由生產廠配套,電動機為 Y係列或 YB係列電壓 380V,功率範圍 0.55~ 11kW。
型號表示方法
電液推杆的推出速度 υ Ⅰ — V≥ 50~70 mm/s Ⅱ — V≥ 70~125mm/s Ⅲ — V≥ 125~200 mm/s Ⅳ — V≥ 200~300 mm/s Ⅴ — V≥ 300 mm/s
電液推杆的最大推力: N 裝置方式: J型; C型自鎖方式代號: J表示機械自鎖;無 J表示液壓自鎖防爆代號: B表示防爆型,無 B為一般型電液推杆代號
( 2) ZDY電液轉角器電液轉角器是一種液壓旋轉擺動部件,通過油泵、液壓集成閥可使液壓缸完成 0° ~90° 、 0° ~ 120° 範圍的旋轉擺動運動,與任何蝶閥、球閥、風門等配套使用,是取代電動頭的更新換代產品。型號表示方法
ZDY □ □ □ A:電機正反轉控製
B:行程控製、信號顯示控製機構 C:遠距離角度控製,數字顯示
D: 4~20mA微機控製
E:微機直控(用於 220V 500W以下電機)額定力矩, N〃 m 有無防爆功能代號, B為防爆型,無 B為一般型電液轉角器(電液頭)
| 規格型號 | L | L1 | L2 | L3 | L4 | L5 | H | D0 | D1 | F | b | h | n-Md |
ZDY5 | 470 | 210 | 90 | 132 | 280 | φ 65 | 135 | 18 | 90 | 20.3 | 5 | 15 | 4-M8 | |
ZDY15 | 520 | 222 | 102 | 152 | 325 | φ 65 | 145 | 20 | 95 | 22.8 | 6 | 15 | 4-M8 | |
ZDY45 | 520 | 255 | 130 | 135 | 480 | φ 76 | 165 | 24 | 100 | 27.3 | 8 | 20 | 4-M12 | |
ZDY85 | 545 | 320 | 160 | 135 | 480 | φ 95 | 210 | 32 | 110 | 35.3 | 10 | 20 | 4-M14 | |
ZDY150 | 545 | 330 | 170 | 135 | 490 | φ 121 | 210 | 38 | 140 | 41.3 | 10 | 25 | 4-M18 | |
ZDY200 | 625 | 340 | 200 | 160 | 625 | φ 133 | 230 | 42 | 160 | 45.3 | 12 | 25 | 4-M18 | |
ZDY300 | 625 | 340 | 220 | 160 | 630 | φ 140 | 230 | 50 | 160 | 53.8 | 14 | 25 | 4-M18 | |
ZDY400 | 695 | 480 | 235 | 230 | 640 | φ 159 | 290 | 60 | 195 | 64.4 | 18 | 30 | 8-M20 | |
ZDY500 | 695 | 505 | 260 | 230 | 640 | φ 184 | 290 | 70 | 235 | 74.9 | 20 | 30 | 8-M20 | |
ZDY600 | 695 | 505 | 260 | 230 | 640 | φ 184 | 290 | 70 | 235 | 74.9 | 20 | 30 | 8-M20 | |
ZDY800 | 695 | 505 | 260 | 260 | 750 | φ 184 | 340 | 70 | 280 | 79.8 | 20 | 30 | 8-M20 | |
ZDY1000 | 695 | 505 | 260 | 260 | 780 | φ 184 | 380 | 76 | 300 | 86.8 | 22 | 30 | 8-M24 | |
ZDY1500 | 750 | 550 | 300 | 290 | 810 | φ 203 | 400 | 98 | 350 | 110.8 | 28 | 35 | 8-M24 | |
ZDY2000 | 750 | 550 | 300 | 290 | 870 | φ 203 | 420 | 120 | 390 | 134.8 | 32 | 35 | 8-M24 | |
ZDY2500 | 815 | 580 | 350 | 320 | 950 | φ 219 | 440 | 120 | 390 | 134.8 | 32 | 40 | 8-M24 | |
ZDY3000 | 815 | 580 | 350 | 320 | 980 | φ 219 | 460 | 120 | 390 | 134.8 | 32 | 40 | 8-M24 |
注:
1.型號後數字表示額定力矩的 1/10(如 ZDY5表示額定力矩 50N〃 m)。
2.用戶按型號表示方法填寫要求,電機為 Y或 YB係列,電壓 380V,功率範圍 0.55~ 11kW。用戶有不明確的或特殊要求的,請與生產單位聯係。
( 3)其他說明
1)電液缸使用、維護注意事項。
勿放置和使用於水淋、過度潮濕、高溫、低溫等工況。
電液缸出廠時,油口蓋內加 O形密封圈,將呼吸口封死,在使用時應將此 O形圈取出
以便於油箱的呼吸。等速回路和等速電液缸可不取下此 O形圈。
電液缸工作介質,建議采用粘度為 25~ 40mm2/s 的抗磨液壓油(一般選用 46#)、透平
油、機油等礦物油,油液要過濾,清潔度要達到 MAS 1638— 9級或 ISO4406— 19/15級以上,工作溫度控製在 15~ 60℃ 範圍內。
電液缸首次使用時,應注意排淨液壓缸內的空氣。當液壓缸活塞杆縮回時,使液壓缸有杆腔和油箱都充滿工作介質。電液缸的油箱很小,一旦出現外泄漏應立即修複,並補足工作介質,因工作介質不足造成液壓泵吸空現象,會很快造成泵的損壞和液壓缸的氣蝕 ! 在電
液缸運行中如出現爬行和振動,應首先檢查是否油液太少、油泵吸空、液壓缸內進入空氣。
溢流閥在出廠時已調整好,請勿隨意調高。超負荷使用,會損壞泵和電機等。
電液缸由於油箱太小,不宜用於連續長時間運轉和頻繁換向的工況,當油箱因連續運轉出現高溫時,應暫停,等冷卻後使用。必須連續長時間運轉和頻繁換向的電液缸,在訂貨時應加以說明,以便在設計時采取防止溫升過高過快的措施。
每年應定期更換一次工作介質。
2)選型有不詳之處或特殊要求,用戶可與生產單位聯係。